Files > DICOM FAILED IMAGES

name
DICOM FAILED IMAGES
number
2006.575
location
^MAGD(2006.575,
description
+---------------------------------------------------------------+ | | | Property of the US Government. | | No permission to copy or redistribute this software is given. | | Use of unreleased versions of this software requires the user | | to execute a written test agreement with the VistA Imaging | | Development Office of the Department of Veterans Affairs, | | telephone (301) 734-0100. | | | | The Food and Drug Administration classifies this software as | | a medical device. As such, it may not be changed in any way. | | Modifications to this software may result in an adulterated | | medical device under 21CFR820, the use of which is considered | | to be a violation of US Federal Statutes. | | | +---------------------------------------------------------------+ The entries in this table describe image files that were received by the DICOM Image Gateway, and could not be matched with a patient and an ordered study. The MAGD FIX DICOM FILE and MAGD FIX MEDICINE DICOM FILE menu options are used to update the entries in this file. The DICOM Image Gateway will poll this file for corrected entries. The cross reference used to poll this information is ^MAGD(2006.575,"AFX". The routine L^MAGDLB1 is used by the above menu options and will loop thru the following cross reference ^MAGD(2006.575,"F". This cross reference is set by the DICOM Study Instance UID; this is a unique number assigned by modalities (imaging equipment) and is unique by case study. So it is possible to have over 20 entries in the file and only one unique "F" cross reference.
Fields
#NameLocationTypeDetailsIndexDescription
.01filepath(+)0;1FREE TEXTBThis is the full name, including the directory path, of the image file that failed the matching process on the local DICOM Image gateway processing the image.
1failed reason0;2SET OF CODESNO CASE #:No case number
PID ERROR:Could not match patient
UNKNOWN:Any other reason
BAD CASE #:Format error in case number
CANCELLED:Case cancelled
The value of this field is a code that indicates the reason why the image file that is described in the current entry could not be matched with a patient and study. The possible values for this field are NOCASE#, PATIENT, UNKNOWN or CANCELLED. When the entry is processed the match for the Radiology entry is by case number and then by patient ID. If these entries are not provided correctly then entries are made into this file.
2pid0;3FREE TEXTThe value of this field is the value that is transmitted by the modality for DICOM element 0010,0020. Typically, the value of this field is equal to the Social Security Number of the patient for whom the study is scheduled. (Without the dashes between the number-groups.) This value is copied from the VistA Database, so that worklist queries can also be performed when the network connection (DDP) with the main Hospital Information System is not available.
3patient0;4FREE TEXTThe value of this field is a string that represents the name of the patient. This value is reformatted as LAST NAME,FIRST NAME MID. The actual name sent by the Radiology modality is in field PNAMEDCM. This field will be used as one of the possible lookups for correction to this entry.
4pnamedcm0;5FREE TEXTThe value of this field is a string that represents the name of the patient. This value is copied from the information that was transmitted by the Radiology modality.
5casenumb1;1FREE TEXTThe value of this field is a string that represents the case number for the study. This value is copied from the information that was transmitted by the Radiology X-Ray equipment.
6case no.1;2FREE TEXTThe value of this field is a string that represents the case number for the study. This value is copied from the information that was entered by the technician during the image capture at the Radiology X-Ray modality. This field will usually be empty since the file will contain only entries that failed during the copying of images to the Imaging file.
7date entered1;3DATE-TIMEThe value of this field is a date value. This value must be an exact date and represents the date on which the entry was made into this file.
8image uidAIUID;1FREE TEXTThe value of this field is a string that represents the Image UID. This value is copied from the information that is transmitted by the modality. The Image UID is a unique ID number assigned to the image by the Radiology X-Ray modality.
9study uidASUID;1FREE TEXTThe value of this field is a string that represents the Study UID. This value is copied from the information that is transmitted by the modality. The Image UID is a unique ID number assigned to the image by the Radiology X-Ray modality. A case study will consist of several images, each of which has its own unique Image UID code.
10instrument nameAMFG;1FREE TEXTThe value of this field is a string that represents the name of the instrument that produced the image file. Typical values for this field are texts like CT1, CT2, CR3, and so forth.
11rowsAMFG;2FREE TEXTThe value of this field is an integer number that represents the number of pixel rows in the image. This value is copied from the information that is transmitted by the Radiology modality.
12columnsAMFG;3FREE TEXTThe value of this field is an integer number that represents the number of pixel columns in the image. This value is copied from the information that is transmitted by the Radiology modality.
13offsetAMFG;4FREE TEXTThe value of this field is an integer number that represents the byte address in the image file where the image data begins. This value is copied from the information that is transmitted by the Radiology modality.
14modienAMFG;5FREE TEXTThe value of this field is a pointer to the Modality file (# 2006.582, stored in ^MAGDICOM(2006.582,...). This value identifies the modality (type of instrument) that transmitted the image file.
16fixedFIXD;1BOOLEAN1:YES
The value of this field is a code that identifies whether or not the problem that is reported in the current entry has been corrected. Entries are corrected in this file using either of the menu options MAGD FIX DICOM or MAGD FIX MEDICINE When the entry is manually matched with a patient and procedure the correction routine will update this field.
17newdfnFIXD;2FREE TEXTThe value of this field is a pointer to the Patient file (# 2, stored in ^DPT(...). This value identifies the (new) patient, and is defined using either of the menu options MAGD FIX DICOM or MAGD FIX MEDICINE
18newnmeFIXD;3FREE TEXTThe value of this field is a string that represents the name of a patient. This value identifies the (new) patient, and is defined using either of the menu options MAGD FIX DICOM or MAGD FIX MEDICINE
19newssnFIXD;4FREE TEXTThe value of this field is a string that represents the Social Security Number of a patient. This value identifies the (new) patient, and is defined using either of the menu options MAGD FIX DICOM or MAGD FIX MEDICINE
20newcase noFIXD;5FREE TEXTThe value of this field is a string that represents the accession number for a study. This value identifies the (new) study, and is defined using either of the menu options MAGD FIX DICOM or MAGD FIX MEDICINE
21new radtiFIXD;6FREE TEXTThe value of this field is a string that represents the date and time when the study was executed. This value is a 'reverse' date time, as defined by the Radiology software. It is used as the second subscript (RADTI) in references like ^RARPT(RADPT,"DT",RADTI,"P",RACNI This value timestamps the (new) study, and is defined using either of the menu options MAGD FIX DICOM or MAGD FIX MEDICINE
22new racniFIXD;7FREE TEXTThe value of this field is a string that represents the case number for the study. This value is used as the third subscript (RADCNI) in references like ^RARPT(RADPT,"DT",RADTI,"P",RACNI This value identifies the (new) study, and is defined using either of the menu options MAGD FIX DICOM or MAGD FIX MEDICINE
23date/timeFIXD;8FREE TEXTThe value of this field is a string that represents a date/time value. This value is copied from the information that was transmitted by the Radiology modality. It is a timestamp for the moment when the image file was processed.
24new proc ienFIXPR;1FREE TEXTThe value of this field is a pointer to the Rad/Nuc procedure file (#71, stored in ^RAMIS(71,...). This value is an internal entry number, and is defined using either of the menu options MAGD FIX DICOM or MAGD FIX MEDICINE
25new procedureFIXPR;2FREE TEXTThis is the new procedure name defined using the MAGD FIX DICOM or MAGD FIX MEDICINE menu option. The value of this field is a string that represents the name of a procedure found in the Rad/Nuc procedure file (#71, stored in ^RAMIS(71,...). This value is the name of a procedure, and is defined using either of the menu options MAGD FIX DICOM or MAGD FIX MEDICINE
26related imagesRLATE;0MULTIPLE2006.57526This is the multiple sub-file that repoints to this file. This sub-file will point to all the related images having the same study instance UID.
27modalityAMFG;6FREE TEXTThe value of this field is a string that represents the name of a modality. This value represents the name of the modality (i.e., the type of of instrument) for the images requiring manual correction.
28machine id1;4FREE TEXTThis is the name of the VistA DICOM Image Gateway computer that received the image file.
29commentACSTXT;1FREE TEXTThe value of this field is a string that represents a comment. This value is copied from the information that was transmitted by the Radiology equipment. Typically, this value contains the accession number.
30image pointerFIXPR;3NUMERICThe value of this field is a pointer to the Image file (#2005, stored in ^MAG(2005,...). This value identifies the image that is the 'parent' of the group to which the image that is described in this entry belongs.
31parent fileFIXPR;4NUMERICThe value of this field is a pointer to the File of Files (#1, stored in ^DIC(...). This value identifies the Imaging Parent file that contains the clinical information of which the image file that is described in this entry is a part. Possible parent files are: 3.9 MAIL MESSAGE 63 AUTOPSY (MICROSCOPIC) 63.02 ELECTRON MICROSCOPY 63.08 SURGICAL PATHOLOGY 63.09 CYTOLOGY 63.2 AUTOPSY (GROSS) 74 RADIOLOGY 130 SURGERY 691 ECHOCARDIOGRAM 691.1 CARDIAC CATHETERIZATION 691.5 ELECTROCARDIOGRAPHY 694 HEMATOLOGY 699 ENDOSCOPY 699.5 GENERIC MEDICINE 8925 TIU
32service typeTYPE;1FREE TEXTThe value of this field is a string that identifies the 'imaging service' that is performed by the instrument that is described in this entry. The imaging services are itemized in file 2006.589 (stored in ^MAGDICOM(2006.589,...) Currently, the only entries in this file are RAD and MED-ENDO.
33delete flag0;6SET OF CODES1:FILE IS DELETED
The value of this field is a code that indicates whether of not the image file that is described in this entry is to be deleted. Corrections are made using either of the menu options MAGD FIX DICOM or MAGD FIX MEDICINE If the images files are for a test patient, then setting this field will not process the images but delete the files from the DICOM Image gateway.
34manufacturerAMFG;7FREE TEXTThe value of this field is a string that identifies the manufacturer of the instrument that transmitted the images that require manual correction.
35modelAMFG;8FREE TEXTThe value of this field is a string that identifies the model of the instrument that transmitted the images that require manual correction.
36gateway location1;5POINTER4This field will contain the institution where the gateway is located.
37instrument siteAMFG;9FREE TEXTThis field will contain the institution where the instrument is located.

Referenced by 1 types

  1. DICOM FIXED QUEUE (2006.5712) -- image, study