Files > IMAGING WINDOWS WORKSTATIONS

name
IMAGING WINDOWS WORKSTATIONS
number
2006.81
location
^MAG(2006.81,
description
+---------------------------------------------------------------+ | | | Property of the US Government. | | No permission to copy or redistribute this software is given. | | Use of unreleased versions of this software requires the user | | to execute a written test agreement with the VistA Imaging | | Development Office of the Department of Veterans Affairs, | | telephone (301) 734-0100. | | | | The Food and Drug Administration classifies this software as | | a medical device. As such, it may not be changed in any way. | | Modifications to this software may result in an adulterated | | medical device under 21CFR820, the use of which is considered | | to be a violation of US Federal Statutes. | | | +---------------------------------------------------------------+ The Imaging Windows Workstations file is used by the Imaging System Manager. This file will contain an entry for any workstation that has connected to this site during an Imaging Session. The Workstation information is stored in this file. identified to automatically update its Imaging software. The Imaging System manager at the Medical Centers should periodically review this file to ensure that all the workstations have the latest code. Note: The information in this file should not be edited.
Fields
#NameLocationTypeDetailsIndexDescription
.01name(+)0;1FREE TEXTBThe network computer name as defined through MS Windows.
.04place1;2POINTER2006.1CThis field references the site parameter file. The Site parameter entry defines all of the attributes of Vista Imaging local area network. This includes facility user preferences, network write locations, etc.
1last user0;2POINTER200The last user to logon to VistA using VistA Imaging GUI Applications from this workstation.
2last logon dttm0;3DATE-TIMEThe last date and time that a user logged on to VistA using the VistA Imaging GUI Applications from this workstation.
3last logoff dttm0;4DATE-TIMEThe last date and time that a user logged off of VistA using the VistA Imaging GUI Applications from this workstation.
5display app dttm0;6DATE-TIMEThis field indicates when the Clinical Display client application, which is installed on this workstation, was built. This data is reported by the application when it connects to the server from the workstation.
5.3telereader app dttm2;2DATE-TIMEThis field indicates when the TeleReader client application, which is installed on this workstation, was built. This data is reported by the application when it connects to the server from the workstation.
5.5capture app dttm0;5DATE-TIMEThis field indicates when the Clinical Capture client application, which is installed on this workstation, was built. This data is reported by the application when it connects to the server from the workstation.
5.7vistarad app dttm2;3DATE-TIMEThis field indicates when the VistA RAD client application, which is installed on this workstation, was built. This data is reported by the application when it connects to the server from the workstation.
5.9clinical utilities app dttm2;1DATE-TIMEThis field indicates when the Clinical Utilities client application, which is installed on this workstation, was built. This data is reported by the application when it connects to the server from the workstation.
6location of wrks1;1FREE TEXTThe location of the workstation as defined in the MAG.INI file, Section: [SYS_SiteParam] entry: Location= When a Site Manager is setting up the Imaging workstation for the first time, they should enter a brief description of the location of the workstation. i.e. Exam Room 232A
7magsetup dttm0;7DATE-TIMEThis is the date/time of the MAGSETUP.EXE File that was last run on this workstation
8active0;8SET OF CODES1:ON-Line
0:not
ADThis field tells whether an Imaging session (Display or Capture) is currently active on the workstation. 1 = Session is active It is modified each time a user logs on via the Imaging application, and set to 0 when the user logs off. (If the Imaging application crashes, it'll still be set and will give false impression that the Imaging application is still active) It is set to 0 when the application quits (if it quits correctly). The value of this field is checked and fixed when the Imaging System Manager ( alpha version ) Imaging session viewer is run from any workstation.
9display version0;9FREE TEXTThis field stores the version number reported by the Clinical Display client during its latest execution from the workstation.
9.3telereader version0;16FREE TEXTThis field stores the version number reported by the TeleReader client during its latest execution from the workstation.
9.5capture version0;13FREE TEXTThis field stores the version number reported by the Clinical Capture client during its latest execution from the workstation.
9.7vistarad version0;15FREE TEXTThis field stores the version number reported by the VistA RAD software during its latest execution from the workstation.
9.9clinical utilities version0;17FREE TEXTThis field stores the version number reported by the Clinical Utilities client during its latest execution from the workstation.
10session0;10POINTER2006.82This is a pointer to the Imaging Windows Session file, which holds statistical information about each Imaging session. It points to the last Imaging Session run on this workstation.
11session error0;11NUMERICThis holds a count of Errors trapped during the current session.
12session count0;12NUMERICThis field is incremented by 1, each time an Imaging session is connected to VistA from this workstation. It is a total count of Imaging sessions run on this workstaion. (Total count of sessions since version 2.5 was installed)
12.5import count0;14NUMERICThis is a count of the number of times the Import API was called with This Workstation as the Acquisiton Device.
13os version1;3FREE TEXTThis is the Operation System installed on this workstation.

Referenced by 1 types

  1. IMAGING WINDOWS SESSIONS (2006.82) -- workstation