# | Name | Location | Type | Details | Index | Description |
---|---|---|---|---|---|---|
.01 | site/specimen | 0;1 | POINTER | 61 | B | Processing specimen type for each entry in the Lab Collection Sample field. Example: Sodium can be determined on serum and urine. To enter a Site/specimen, a Data name must be entered. |
1 | reference low | 0;2 | FREE TEXT | This is the user entered reference low value for this test. If both the low and high are defined it will print in this manner: low : 10 high : 50 If only the low is defined and it is numeric it will print in this manner: low: 10 If only the low is defined and it is alphanumeric it will print in this manner: NORMAL If only the high is defined and it is numeric it will print in this manner: high: 50 If only the high is defined and it is alphanumeric it will print in this manner: >1000 | ||
2 | reference high | 0;3 | FREE TEXT | This is the user entered reference high value for this test. If both the low and high are defined it will print in this manner: low : 10 high : 50 If only the low is defined and it is numeric it will print in this manner: low: 10 If only the low is defined and it is alphanumeric it will print in this manner: NORMAL If only the high is defined and it is numeric it will print in this manner: high: 50 If only the high is defined and it is alphanumeric it will print in this manner: >1000 | ||
3 | critical low | 0;4 | FREE TEXT | This is the user entered critical low value for this test. Used to flag results. If both the low and high are defined it will print in this manner: low : 10 high : 50 If only the low is defined and it is numeric it will print in this manner: low: 10 If only the low is defined and it is alphanumeric it will print in this manner: NORMAL If only the high is defined and it is numeric it will print in this manner: high: 50 If only the high is defined and it is alphanumeric it will print in this manner: >1000 | ||
4 | critical high | 0;5 | FREE TEXT | This is the user entered critical high value of this test. Used to flag results. If both the low and high are defined it will print in this manner: low : 10 high : 50 If only the low is defined and it is numeric it will print in this manner: low: 10 If only the low is defined and it is alphanumeric it will print in this manner: NORMAL If only the high is defined and it is numeric it will print in this manner: high: 50 If only the high is defined and it is alphanumeric it will print in this manner: >1000 | ||
5.5 | interpretation | 1;0 | WORD-PROCESSING | Enter any remark to accompany EVERY test result. These remarks may be edited and formatted with the FileMan text editor. The text may be other range information, special conditions, etc. edited and formatted with the FileMan text editor. The text may be other range information, special conditions, etc. | ||
6 | units | 0;7 | FREE TEXT | UNITS represents such things as grams, number of items per cubic millimeter, or microliter. | ||
7 | type of delta check | 0;8 | POINTER | 62.1 | Points to DELTA CHECK file. | |
8 | delta value | 0;9 | FREE TEXT | DELTA VALUE is the value that is passed to the Delta Check Code. | ||
9 | default value | 0;10 | FREE TEXT | Leave blank or enter the most common (say, >80% of the time) response for the test. | ||
9.2 | therapeutic low | 0;11 | FREE TEXT | This is the low end value of the therapeutic range. Used to flag results. If both the low and high are defined it will print in this manner: low : 10 high : 50 If only the low is defined and it is numeric it will print in this manner: low: 10 If only the low is defined and it is alphanumeric it will print in this manner: NORMAL If only the high is defined and it is numeric it will print in this manner: high: 50 If only the high is defined and it is alphanumeric it will print in this manner: >1000 | ||
9.3 | therapeutic high | 0;12 | FREE TEXT | This is the high end value of the therapeutic range. Used to flag results. If both the low and high are defined it will print in this manner: low : 10 high : 50 If only the low is defined and it is numeric it will print in this manner: low: 10 If only the low is defined and it is alphanumeric it will print in this manner: NORMAL If only the high is defined and it is numeric it will print in this manner: high: 50 If only the high is defined and it is alphanumeric it will print in this manner: >1000 | ||
10 | *amis/rcs 14-4 | 2;0 | MULTIPLE | 60.06 | No longer used. Will be deleted after this version | |
13 | use for reference testing | .1;1 | BOOLEAN | 0:NO 1:YES | Indicates if the reference ranges and units associated with this specimen type can be used when manually entering results of testing performed at another laboratory. | |
20 | foreign computer system | 4;0 | MULTIPLE | 60.2 | Reserved for future use. Do not use. | |
95.3 | loinc code | 95.3;1 | POINTER | 95.3 | AF | This field contains the pointer to the LAB LOINC (#95.3) file. |
96 | specimen cpt | 3;0 | MULTIPLE | 60.196 |
Error: Invalid Global File Type: 60.01