Files > RECORD OF PROS APPLIANCE/REPAIR

name
RECORD OF PROS APPLIANCE/REPAIR
number
660
location
^RMPR(660,
description
This is the main file for prosthetic purchasing transactions. AMIS is calculated from this file based on item issued and disability served. This file is also the permanent record for the patient VAF 10-2319 of items issued to the veteran.
Fields
#NameLocationTypeDetailsIndexDescription
.01entry date(+)0;1DATE-TIMEBThis is the date that the transaction was entered into the system. It may or may not be the same as the request date.
.02patient name(+)0;2POINTER665CThis is the name of the patient that this transaction is for. The name is a pointer to the PROSTHETIC PATIENT file which has the same internal entry number as the main patient database.
1request date(+)0;3DATE-TIMEThis field is the date the appliance issue or repair was requested by the patient. It may or may not be the same as the entry date or the delivery date. This depends on how quickly the transactions take place.
2type of transaction(+)0;4SET OF CODESI:INITIAL ISSUE
R:REPLACE
S:SPARE
X:REPAIR
5:RENTAL
This set of codes will tell what kind of transaction this request is. The possibilities all fall under the VAF 10-7306a listings except for the repair.
4item(+)0;6POINTER661ADThis field is a pointer to the master item list of possible appliances. The master list is set up so that appliances fall into groups which are the types of appliances.
4.1hcpcs(+)0;22POINTER81GHealth Care Financing Administration Common Procedure Coding System (HCPCS). This field should have the HCPCS code for the Item you are selecting. HCPCS is a uniform method for healthcare providers and medical suppliers to report professional services, procedures and supplies.
4.2vendor tracking number4;1FREE TEXTThis field is the Vendor's internal unique tracking number. Some of the small vendors are not automated with VISA, and this tracking number is used to reference this transaction. This tracking number is based on the item, and can be as simple as the vendors item number, or elaborate as the vendors transaction number. This data will be used in the reconciliation process.
4.3bank authorization number4;2FREE TEXTThis six digit number is the authorization number VISA gives to the vendor for guaranteed payment. This number is used in the reconciliation process.
4.5psas hcpcs1;4POINTER661.1HStandardized Prosthetics HCPCS that points to file 661.1.
4.6stock issue1;5POINTER661.6This is a pointer to file #661.6.
4.7cpt modifier1;6FREE TEXTCPT Modifiers in a comma delimited format, consistent with the HCFA published manuals.
4.8date cpt modifier extracted1;7DATE-TIMEThis is the date the patient record extracted for billing. This date is also being used to trigger a mail message to billing if the PSAS HCPCS is edited and changed after the extraction has been ran.
4.9hcpcs-icd9 coding flag1;11NUMERICThis field is used to determine the current code set versioning of a transaction. No errors, number 1. PSAS HCPCS, Not Billiable Item, number 14. ICD9 error, number 12. HCPCS error, number 13. Both ICD9 and HCPCS error, number 132. Both ICD9 error and Not Billiable Item, number 142.
4.91coding flag date1;12DATE-TIMEThis is the date associated with field number 4.9. The date the coding flag was set.
4.92high tech item1;13BOOLEAN1:YES
0:NO
This is the determination by the Prosthetics Laboratory Technician. 1=YES 0=NO
5qty(+)0;7NUMERICThis is the number of units that was issued or repaired for this transaction.
6ship/del0;17NUMERICThis is the charge associated with shipping.
6.5pickup/del0;26SET OF CODESP:PICKUP
D:DELIVERY
This field is a set of codes to identify pickup/delivery charges on VAF 10-2319.
7vendor(+)0;9POINTER440The vendor is a pointer to IFCAP's VENDOR file and is the name of the company from which this appliance was or is to be purchased. The vendor may or may not be the same as the manufacturer. Therefore, manufacturers should also be listed in this file as vendors if you are going to be purchasing directly from the manufacturer.
8station(+)0;10POINTER4The station is the Veterans Affairs site where this transaction is to come to completion. It is the station that is ultimately responsible for the issue and payment for the prosthetic device. This is the station reporting the workload.
8.1suspense date10;1DATE-TIMEThis is suspense date (.01 field) of file (#668).
8.11suspense station10;11POINTER4This refers to the consulting station.
8.12pce10;12POINTER9000010This field is pointer to (Patient Encounter), Visit file (#9000010). When an entry is created in PCE a pointer is being set.
8.13date sent to pce10;13DATE-TIMEIThis is the date last sent or edited in PCE. If PCE is deleted this field should be deleted.
8.14suspense status10;14SET OF CODES0:INCOMPLETE
1:COMPLETE
This is the suspense status of the patient 2319 record. If the status is complete, a suspense link was established. If the status is incomplete, there is no suspense link to the patient 2319 record.
8.2date rx written10;2DATE-TIMEThis is the date the prescription was written as it appears in file #668.
8.3initial action date10;3DATE-TIMEThis field is the date when an initial action was entered in suspense.
8.4completion date10;4DATE-TIMEThis is the date the susepnse was completed as it appears in file #668.
8.5type of request10;5FREE TEXTThis field could either be ROUTINE PROSTHETICS, EYEGLASS, CONTACT LENS, OXYGEN, MANUAL NON CPRS or CLOTHING ALLOWANCE.
8.6suspense requestor10;6POINTER200This is a pointer to file #200, the person requesting the suspense as it appears in file #668.
8.61consult request service4;3FREE TEXTA service/section of a suspense requestor that initiated a consult for Prosthetics item. This free text entry is a service/section name of SERVICE/SECTION file (#49).
8.7provisional diagnosis10;7FREE TEXTThis is a free text diagnosis as it appears in suspense file.
8.8suspense icd10;8POINTER80This is the code at the time suspense was created.
8.9consult10;9POINTER123This is a pointer to Consult file #123.
9serial nbr0;11FREE TEXTThis is the serial number of the issued or repaired appliance. If the serial number is longer than 20 characters, use the FIRST 20 characters.
9.1product description9;1FREE TEXTThe manufacture product description to be used for recalls.
9.2product model9;2FREE TEXTThe manufacture product model number to be used for recalls.
10delivery date0;12DATE-TIMECTThis is the date that the appliance was delivered and accepted by the patient. This date, under certain circumstances, may be a date that the appliance was mailed to the patient. It may or may not be the same as the transaction date and/or the request date.
11form requested on0;13SET OF CODES1:PSC
2:2421
3:2237
4:2529-3
5:2529-7
6:2474
7:2431
8:2914
9:OTHER
10:2520
11:STOCK ISSUE
12:INVENTORY ISSUE
13:HISTORICAL DATA
14:VISA
15:LAB ISSUE-3
16:DALC
The FORM REQUESTED ON is based on current VA regulations. The system makes no checks to be sure that the form entered from the set of codes is within these regulations.
12source(+)0;14SET OF CODESV:VA
C:COMMERCIAL
This set of codes denotes which two possible sources were used for the acquisition of the appliance. The sources are grouped into either VA sources or commercial sources.
13action0;5SET OF CODES1:LOAN
2:CONDEMNED
3:RETURNED
4:INACTIVE
5:LOST
The action taken on this transaction is noted here. The set of codes is self explanatory; however, the inactive action is used to indicate that the appliance is no longer being followed by VA.
14total cost(+)0;16NUMERICThis field contains the total cost of the transaction.
15historical data0;15FREE TEXTIf this field contains an asterisk (*), then this transaction has been counted by the AMIS option, or is considered to be a historical transaction.
16remarks0;18FREE TEXTA free-text field used to indicate any additional information that is needed for this entry. For Purchasing Transactions this field will contain the remarks for the individual item, and the close-out remarks added together.
17returned status0;19SET OF CODES1:RETURNED
2:CONDEMNED
3:CANCELLED
4:TURNED-IN
5:LOST
6:BROKEN
The status of the appliance upon return to the veteran. This notes what action was taken by the repair depot or station upon the completion of repairs.
17.5return status date0;20DATE-TIMEThis is the date upon which the return status was determined and carried out if the item was returned to the veteran.
18*status flag0;21SET OF CODESD:DECEASED
T:TRANSFERRED
I:INACTIVE
The status of the patient is entered here so the service can determine if the patient is being followed, dropped, transferred, or canceled by this station.
19patient notification flag3;3SET OF CODES1:RE-SEND
DVNThis field if set to 1 will be used to gather the patient records that need to be re-sent for the daily pull of the Mandatory Patient Notification process.
20delivery verification date6;1DATE-TIMEThis is the date the Veteran indicates on the Notification card that he received the item.
20.1delivery verification status6;2SET OF CODES1:RECEIVED
2:NOT RECEIVED
3:DAMAGED or INCOMPLETE
4:RECEIVED not as ORDERED
5:RECEIVED in ERROR
This is the statement of receipt that the Veteran indicates on the returned Delivery Notification Card.
21lot number0;24FREE TEXTThis field stores the lot number of the item being furnished to the patient. Enter the manufacturer's lot number, if known.
22*product line0;25SET OF CODES1:HEARING AIDS
2:BATTERIES
3:OTHER
Set of codes that contains information for Hearing Aid transactions.
23transaction1;1FREE TEXTEThis is the IFCAP transaction number from VAF 4-1358 or VAF 2237. A temporary Transaction number for a VAF 10-2529-3 may also be entered.
24description1;2FREE TEXTThis is a detailed description of the item/service supplied.
25deliver to3;1FREE TEXTDelivery location that will print on VAF 10-2421 to show the vendor where the item will be delivered.
26date required3;2DATE-TIMEThis field stores the date the vendor is required to provide the Item/Service by.
27initiator0;27POINTER200This is the person who created the transaction.
28extended descriptionDES;0WORD-PROCESSINGThis is the extended information from purchasing and also from posting of VAF 2237s.
29inventory point1;3POINTER445This is the inventory point for this transaction and is a pointer to the GENERIC INVENTORY file (#445).
30primary icd diagnosis codeBA1;1POINTER80This is the primary diagnosis code for the order.
30.1primary agent orange exposureBA1;2BOOLEAN0:NO
1:YES
Primary diagnosis is related to Agent Orange exposure.
30.2primary ionized radiationBA1;3BOOLEAN0:NO
1:YES
Primary diagnosis is related to Ionized Radiation exposure.
30.3primary service-connectedBA1;4BOOLEAN0:NO
1:YES
Primary diagnosis is related to a Service-Connected condition.
30.4primary environmental cont.BA1;5BOOLEAN0:NO
1:YES
Primary diagnosis is related to Environmental Contaminants exposure.
30.5primary mstBA1;6BOOLEAN0:NO
1:YES
Primary diagnosis is related to Military Sexual Trauma.
30.6primary head/neck cancerBA1;7BOOLEAN0:NO
1:YES
Primary diagnosis is related to Head/Neck Cancer.
30.7primary combat vetBA1;8BOOLEAN0:NO
1:YES
Primary diagnosis related to Combat.
31secondary icd diagnosis code 1BA2;1POINTER80This is the secondary diagnosis code 1.
31.1secondary agent orange 1BA2;2BOOLEAN0:NO
1:YES
Secondary diagnosis 1 is related to Agent Orange exposure.
31.2secondary ionized radiation 1BA2;3BOOLEAN0:NO
1:YES
Secondary diagnosis 1 is related to Ionized Radiation exposure.
31.3secondary service-connected 1BA2;4BOOLEAN0:NO
1:YES
Secondary Diagnosis 1 is related to a Service-Connected condition.
31.4secondary environmental cont 1BA2;5BOOLEAN0:NO
1:YES
Secondary diagnosis 1 is related to Environmental Contaminants exposure.
31.5secondary mst 1BA2;6BOOLEAN0:NO
1:YES
Secondary diagnosis 1 is related to Military Sexual Trauma.
31.6secondary head/neck cancer 1BA2;7BOOLEAN0:NO
1:YES
Secondary diagnosis 1 is related to Head/Neck cancer.
31.7secondary combat vet 1BA2;8BOOLEAN0:NO
1:YES
Secondary diagnosis 1 is related to Combat.
32secondary icd diagnosis 2BA3;1POINTER80This is the secondary diagnosis code 2.
32.1secondary agent orange 2BA3;2BOOLEAN0:NO
1:YES
Secondary diagnosis 2 is related to Agent Orange exposure.
32.2secondary ionized radiation 2BA3;3BOOLEAN0:NO
1:YES
Secondary diagnosis 2 is related to Ionized Radiation exposure.
32.3secondary service-connected 2BA3;4BOOLEAN0:NO
1:YES
Secondary diagnosis 2 is related to a Service-Connected condition.
32.4secondary envir. cont. 2BA3;5BOOLEAN0:NO
1:YES
Secondary diagnosis 2 is related to Environmental Contaminants exposure.
32.5secondary mst 2BA3;6BOOLEAN0:NO
1:YES
Secondary diagnosis 2 is related to Military Sexual Trauma.
32.6secondary head/neck cancer 2BA3;7BOOLEAN0:NO
1:YES
Secondary diagnosis 2 is related to Head/Neck cancer.
32.7secondary combat vet 2BA3;8BOOLEAN0:NO
1:YES
Secondary diagnosis 2 is related to Combat.
33secondary icd diagnosis 3BA4;1POINTER80This is the secondary diagnosis code 3.
33.1secondary agent orange 3BA4;2BOOLEAN0:NO
1:YES
Secondary diagnosis 3 is related to Agent Orange exposure.
33.2secondary ionized radiation 3BA4;3BOOLEAN0:NO
1:YES
Secondary diagnosis 3 is related to Ionized Radiation exposure.
33.3secondary service-connected 3BA4;4BOOLEAN0:NO
1:YES
Secondary diagnosis 3 is related to a Service-Connected condition.
33.4secondary environ. cont. 3BA4;5BOOLEAN0:NO
1:YES
Secondary diagnosis 3 is related to Environmental Contaminants exposure.
33.5secondary mst 3BA4;6BOOLEAN0:NO
1:YES
Secondary diagnosis 3 is related to Military Sexual Trauma.
33.6secondary head/neck cancer 3BA4;7BOOLEAN0:NO
1:YES
Secondary diagnosis 3 is related to Head/Neck cancer.
33.7secondary combat vet 3BA4;8BOOLEAN0:NO
1:YES
Secondary diagnosis 3 is related to Combat.
34oif/oef5;1BOOLEAN0:NO
1:YES
Veteran determined to be OEF/OIF 1 Yes 0 NO.
35user who edit1;9POINTER200User who edited the 2319 record using option ED2. This field will only be populated when the Total Cost field has been changed.
36date edited1;10DATE-TIMEThis is the date the Total Cost field has been changed using option ED2.
37hcpcs/item2;1FREE TEXTEnternal entry of an HCPCS concatenated to an enternal entry of an item in file #661.1. Entry for this field is derived from the entry in file 661.2, field #9.
38hcpcs/item description2;2FREE TEXTThis is the description of an Item or Appliance kept by local site in file #661.1, field #20. This field is updated during the STOCK ISSUE options.
38.1exclude/waiver2;3SET OF CODESE:EXCLUDED
W:WAIVER
This field determines if the item is EXCLUDED or Waver off of a National Contract
38.7contract #2;9FREE TEXTThis field stores the Contract Number.
38.8number of bids2;10NUMERICThe number of bids recieved for a particular item.
39date of service1;8DATE-TIMEAFThis is the date when an item is issued to the patient.
40requesting stationLB;1POINTER4This is the station requesting services or appliances.
45total labor hoursLB;6NUMERICThis is the number of hours spent on the job. This field is only populated via routines.
46total labor costLB;7NUMERICThe total cost of the labor to perform this job.
47total material costLB;8NUMERICThe total cost of all the materials to perform the job.
48total lab costLB;9NUMERICThe Prosthetic Laboratory Total Cost calculated by AMIS.
50completion dateLB;11DATE-TIMECDThe date the job was completed.
51lab remarksLB;12FREE TEXTA free-text field used to indicate any additional Laboratory information that is needed for this entry. Since the field is only 40 characters in length, use meaningful abbreviations where possible.
52amis new codeAM;9POINTER663This field is set when AMIS is generated. It is the New Worksheet AMIS code.
60amis dateAM;1DATE-TIMEAEThis field is set when AMIS is generated. This is the date AMIS was run and the item was picked up and counted.
62patient category(+)AM;3SET OF CODES1:SC/OP
2:SC/IP
3:NSC/IP
4:NSC/OP
This is the Prosthetic Patient Category used for counting AMIS.
63special categoryAM;4SET OF CODES1:SPECIAL LEGISLATION
2:A&A
3:PHC
4:ELIGIBILITY REFORM
If the patient is NSC/OP, then this field must also be set. SPECIAL CATEGORY is also used in counting AMIS.
64admin repair amis codeAM;5POINTER663This field will be set when AMIS is generated for the Repair Worksheets.
68amis grouperAMS;1NUMERICAGThis is used in AMIS calculations. This field should never be changed through FileMan!
69source of procurementLB;3SET OF CODESO:ORTHOTIC LAB
R:RESTORATION LAB
S:SHOE LAST CLINIC
W:WHEELCHAIR REPAIR SHOP
N:NATIONAL FOOT CENTER
D:DENVER DISTRIBUTION CENTER
The source from which the Purchasing Agent is ordering the needed equipment. The sources one may choose from are limited.
70receiving stationLB;4POINTER4This field contains the institution that will receive the VAF 10-2529-3 request for processing.
71work order numberLB;5POINTER664.2Work Order Number (STA-FY-QTR-TYPE OF LAB-NUMBER) for items processed in the Prosthetic Laboratory.
722529-3LB;10POINTER664.1VAF 10-2529-3 information will be displayed if the VAF 10-2319 item is associated with a Denver Distribution Center, National Foot Center, or Prosthetics Lab request.
72.5free text wo #LB;2FREE TEXTThis is the actual human readable Work Order Number for NPPD identification purposes.
73lab amis dateLBA;1DATE-TIMELast date the Lab AMIS was run.
74orthotics lab codeLBA;2POINTER663Contains the Orthotic Lab New Code.
75orthotics lab repair codeLBA;3POINTER663Contains the Orthotic Lab Repair Code.
76restoration lab codeLBA;4POINTER663Contains the Restoration Lab New Code.
77restorations lab repair codeLBA;5POINTER663Contains the Restoration Lab Repair Code.
78unit of issue0;8POINTER420.5This is the unit by which items/services are issued (e.g., each, pair, box, case, etc.).
79amis flagAM;6SET OF CODES1:NO ADMIN COUNT
Contains the status if the Item will not count on the Administrative AMIS.
80work for other stationLB;13BOOLEAN1:YES
Contains the Status if the Job Performed will display as work performed for another station.
81no admin countAM;2SET OF CODES1:NO COUNT
This field will be set if the Item will not count on the Administrative AMIS or the Orthotic Laboratory AMIS.
82no lab countLB;14SET OF CODES1:NO COUNT
Field will be set if there is no AMIS Count for AMIS.
83backlog dateLBA;6DATE-TIMEALOGThis field will contain the date that the entry was created. This entry will be a backlog entry until it has been completed. All backlog data must show up on the Laboratory or Restoration AMIS Count.
89historical itemHST;1FREE TEXTThis field is used for the consolidation sites, will contain the data that has been merged from a legacy system. This field is populated by the RMPRJ routine that is not exported.
89.1dalc reference numberHSTV1;3FREE TEXTDDCThis is the line level reference number from a DALC purchase order or delivery of item or service.
89.2dalc bill dateHSTV1;4DATE-TIMEThis is the Billing Date from the Denver Acquisition and Logistics Center (DALC).
89.3dalc ordering stationHSTV1;5FREE TEXTThis is the Ordering station from to the Denver Acquisition and Logistics Center (DALC).
90historical stationHST;2FREE TEXTThis field is used for the consolidation sites, will contain the data that has been merged from a legacy system. This field is populated by the RMPRJ routine that is not exported.
91historical vendorHST;3FREE TEXTThis field is used for the consolidation sites, will contain the data that has been merged from a legacy system. This field is populated by the RMPRJ routine that is not exported.
92historical vendor phoneHSTV;1FREE TEXTThis field is used for the consolidation sites, will contain the data that has been merged from a legacy system. This field is populated by the RMPRJ routine that is not exported.
93historical street addHSTV;2FREE TEXTThis field is used for the consolidation sites, will contain the data that has been merged from a legacy system. This field is populated by the RMPRJ routine that is not exported.
94historical cityHSTV;3FREE TEXTThis field is used for the consolidation sites, will contain the data that has been merged from a legacy system. This field is populated by the RMPRJ routine that is not exported.
95historical stateHSTV1;1FREE TEXTThis field is used for the consolidation sites, will contain the data that has been merged from a legacy system. This field is populated by the RMPRJ routine that is not exported.
96historical zipHSTV1;2FREE TEXTThis field is used for the consolidation sites, will contain the data that has been merged from a legacy system. This field is populated by the RMPRJ routine that is not exported.
97historical recordHST;4NUMERICThis field is used for the consolidation sites, will contain the data that has been merged from a legacy system. This field is populated by the RMPRJ routine that is not exported.
100pfss account referencePFSS;1POINTER375This refers to the reference number passed back to Prosthetics application from the PFSS IBB get account process. This field points to PFSS ACCOUNT file (#375).
101pfss charge idPFSS;2NUMERICA unique charge identifier for each charge entity. Prosthetics calls $$GETCHGID^IBBAPI() to obtain a Unique Charge Identifier.
102latest psas hcpcsPFSS;3POINTER661.1This is the latest PSAS HCPCS code that is held and stored for comparison during the account updates for the PFSS project.
103latest qtyPFSS;4NUMERICThis is the latest QTY that is held and stored for comparison during the account updates for the PFSS project.
104latest total costPFSS;5NUMERICThis is the latest Total Cost that is held and stored for comparison during the account updates for the PFSS project.
105latest ordering providerPFSS;6POINTER200This is the latest attending physician (ordering provider) that is held and stored for comparison during the account updates for the PFSS project.
106pfss account flagPFSS;7SET OF CODES1:READY TO PROCESS
APHFlag for ready to process PFSS Account Creation/Pre-Certification. 1 = Ready to process
107pfss charge flagPFSS;8SET OF CODES1:READY TO PROCESS
APDFlag for ready to process PFSS Charge message. 1 = Ready to process

Referenced by 9 types

  1. CLAIMS TRACKING (356) -- prosthetic item
  2. IB BILL/CLAIMS PROSTHETICS (362.5) -- record
  3. PROS RETURNED/CONDEMNED (660.1) -- appliance repair
  4. PROSTHETICS RE-ISSUE ITEM (660.2) -- appliance repair
  5. PROSTHETIC TRANSACTION PATIENT ISSUE (661.63) -- patient transaction
  6. PROSTHETICS 1358 (664) -- shipping entry
  7. PROSTHETIC WORK ORDER (664.2) -- appliance/repair
  8. PROSTHETIC LAB HOURS DATE (664.3) -- appliance/repair
  9. STATION ORDER (791810) -- prosthetics order