Files > PROFILE

parent
68.2
name
PROFILE
number
68.23
Fields
#NameLocationTypeDetailsIndexDescription
.01profile0;1FREE TEXTBOnly ONE load or work list can exist at a time. But more than one profile can be defined to make "alternate" groupings of tests for the load/worklist which might be used on an infrequent or non-standard basis.
1test1;0MULTIPLE68.24These are the tests to be brought onto the load/work list from the accessions.
2accession area(+)0;2POINTER68This is the default accession area to use to build the load/work list.
2.1uid verification0;3SET OF CODES0:PROFILE ACCESSION AREA ONLY
1:ANY ACCESSION AREA
When verifying by Lab Universal Identifier (UID) the site can configure how accessions are selected. If "PROFILE ACCESSION AREA ONLY" is selected then only those UIDs which are from the accession area designated for this profile can be selected. If "ANY ACCESSION AREA" is selected then a UID from any accession area can be selected. Note that an accession from a different area should have tests that would be in this editing profile.
2.2store duplicate comments0;4BOOLEAN0:NO
1:YES
When the Laboratory result verifying software is processing comments associated with a load/work list result, this field determines how duplicate comments are processed. If set to "NO" (default if no value) then a comment that matches a previously stored comment will not be stored with the result. If set to "YES" then the duplicate check is not performed and the comment is stored with the results irregardless if the comment already exists. Setting it to "YES" will allow the handling of multiple line comments which contain the same comment more than once and are still clinically significant.
2.3default reference laboratory0;5POINTER4The performing laboratory that is commonly associated with this profile. It will be presented as the default performing laboratory when a user is setting up a verifying session using this profile.
3tray # for control2;0MULTIPLE68.25Enter the tray number appropriate for the controls you will next be choosing. If this is a worklist or sequence loadlist, the "tray" is always "1".
4specimen to exclude3;0MULTIPLE68.27If any specimens are specified here, accessions of these specimen(s) will NOT be included on the work/load list.
5controls to begin worklist4;0MULTIPLE68.28This multiple has the controls that are to be placed on the worklist at the beginning of the list.
6controls to end worklist5;0MULTIPLE68.29This multiple has the controls that are to be blaced on the worklist at the end of the list.