# | Name | Location | Type | Details | Index | Description |
---|---|---|---|---|---|---|
.01 | date/time(+) | 0;1 | DATE-TIME | B | This field identifies the specific Atrial Study. | |
.5 | ep record(+) | 0;2 | POINTER | 691.8 | C | This field identifies the electrophysiologic record. |
1 | intervention | 0;3 | POINTER | 693.6 | This describes the intervention associated with this procedure. | |
2 | premedication | 0;4 | FREE TEXT | This documents the medication used prior to the start of this procedure. | ||
3 | ekg | 7;0 | MULTIPLE | 691.93 | This field identifies the EKG's associated with this procedure. | |
4 | entry site | 0;6 | POINTER | 697 | This field describes the catheter entry site used during this procedure. | |
5 | recording site | 0;7 | POINTER | 693.5 | This field documents the anatomical location of the catheter. | |
6 | pacing site | 0;8 | SET OF CODES | HRA:HIGH RIGHT ATRIUM LRA:LOW RIGHT ATRIUM MRA:MID RIGHT ATRIUM CSD:CORONARY SINUS, DISTAL CSP:CORONARY SINUS, PROXIMAL ESO:ESOPHAGEAL PACING | This field identifies the anatomical location of the pacing mechanism. | |
7 | atrial threshold (ma) | 0;9 | NUMERIC | This field identifies the atrial threshold in milliamperes. | ||
8 | p-a interval | 0;10 | NUMERIC | This field identifies the P-A interval. | ||
9 | a-h interval | 0;11 | NUMERIC | This field identifies the A-H interval. | ||
10 | h-v interval | 0;12 | NUMERIC | This field identifies the H-V interval. | ||
11 | drive cycle length | 1;0 | MULTIPLE | 691.911 | This field identifies the drive cycle length. | |
12 | max 1:1 av conduction | 2;1 | NUMERIC | This field identifies the maximum 1:1 AV conduction. | ||
13 | wencke cycle length | 2;2 | NUMERIC | This field identifies the Wencke cycle length. | ||
14 | block site | 2;3 | SET OF CODES | P:PROXIMAL BLOCK D:DISTAL | This field identifies the block site. | |
15 | tachycardia window | 2;4 | FREE TEXT | This field identifies the tachycardia window. | ||
16 | tachycardia cycle length | 2;5 | NUMERIC | This field identifies the tachycardia cycle length. | ||
17 | tachycardia morphology | 2;6 | SET OF CODES | 1:NARROW QRS 2:RBBB 3:LBBB 4:RBBB+LAFB 5:RBBB+LPFB | This field identifies the tachycardia morphology. | |
17.1 | pr interval | 6;2 | NUMERIC | This field identifies the P-R interval. | ||
17.2 | rp interval | 6;3 | NUMERIC | This field identifies the RP interval. | ||
17.3 | rp/pr ratio | COMPUTED | This field identifies the RP/PR ratio. | |||
18 | aberration | 2;7 | SET OF CODES | RBBB:RBBB LBBB:LBBB R+L:RBBB+LBBB | This field identifies the aberration found in this study. | |
19 | sact | 2;8 | NUMERIC | This field identifies the SACT. | ||
20 | csart | 2;9 | NUMERIC | This field identifies the CSART. | ||
21 | bypass tract | 3;0 | MULTIPLE | 691.921 | This field identifies the bypass tract. | |
22 | discharge date | 4;0 | MULTIPLE | 691.922 | This field identifies the discharge date. | |
23 | comment | 5;0 | WORD-PROCESSING | This field identifies the comment field. | ||
24 | cardiology staff | 6;1 | POINTER | 200 | This field identifies the cardiology staff attending this procedure. | |
700 | icd diagnosis | ICD;0 | MULTIPLE | 691.9001 | This field contains the ICD Diagnosis(es) for the procedure. | |
701 | primary provider | PROV;1 | POINTER | 200 | This contains the primary provider. It is triggered by another field in the file and is located here to provider a standard provider location for use in transferring data to the PCC. |
Not Referenced