# | Name | Location | Type | Details | Index | Description |
---|---|---|---|---|---|---|
.01 | id(+) | 0;1 | FREE TEXT | This value is a Global Unique IDentifier (GUID) for this alarm. The GUID is maintained nationally so this value represents this item throughout the enterprise. | ||
.02 | patient id(+) | 0;2 | POINTER | 2 | This identifies the patient for which this alarm (#.01) is applicable. | |
.03 | term id(+) | 0;3 | POINTER | 704.101 | This is the term to be monitored when the Clinical Flowsheets application determines whether to signal an alarm. | |
.04 | unit id | 0;4 | POINTER | 704.101 | This identifies the unit of measurement to use when Clinical Flowsheets compares observed and "alarm" values. | |
.05 | alarm type(+) | 0;5 | SET OF CODES | 0:Value in range 1:Value not in range 2:Value greater than 3:Value less than 4:Value in Picklist 5:Value is True 6:Value is False | This indicates the case, when satisfied by an observed value, for the assigned patient and term, that may cause the Clinical Flowsheets application to trigger the alarm (#01). | |
.06 | min value | 0;6 | NUMERIC | This field is the minimum value for this term (#.03) and unit(#.04) that will not trigger the alarm (#.01). | ||
.07 | max value | 0;7 | NUMERIC | This field is the maximum value for this term (#.03) and unit(#.04) that will not trigger alarm. | ||
.08 | alarm set | 0;8 | BOOLEAN | 0:No 1:Yes | This indicates whether or not this alarm's (#.01) conditions are satisfied. | |
.09 | active(+) | 0;9 | BOOLEAN | 0:No 1:Yes | This indicates if this alarm (#.01) logic is to be executed on new values (reset). | |
.11 | activated date time(+) | .1;1 | DATE-TIME | This field is the date/time this alarm (#.01) is to be activated. | ||
.12 | activated by id(+) | .1;2 | POINTER | 200 | This identifies the person (file #200) that activated this alarm (#.01). | |
.13 | deactivated date time | .1;3 | DATE-TIME | This is the date/time this alarm (#.01) is to be deactivated. | ||
.14 | deactivated by id | .1;4 | POINTER | 200 | This identifies the person (file #200) that deactivated this alarm (#.01). | |
.2 | activated comment(+) | .2;1 | FREE TEXT | This is the comment entered when this alarm (.01) was activated. A sample ACTIVATED COMMENT could be "Alarm activated for automated monitoring". | ||
.3 | deactivated comment | .3;1 | FREE TEXT | This is the comment entered when this alarm (.01) was deactivated. A sample DEACTIVATED COMMENT could be "Alarm deactivated for staff monitoring". | ||
.4 | picklist ids | .4;1 | FREE TEXT | This field is a list of VA Unique IDentifiers for a "picklist-type" observation. A sample PICKLIST IDS could be: "{65069804-39BF-41ED-9EA3-BF2C41389F10},{715091C2-9668-4678-900E-6D55 D3335A30},{D5B3E135-4D68-4528-BBC9-6E8A7A997104}" |