# | Name | Location | Type | Details | Index | Description |
---|---|---|---|---|---|---|
.01 | event monitor ien (free-text) | 0;1 | FREE TEXT | B | This field holds the internal entry number of the monitor entry in the HL Event Monitor file (#776.1). NOTE: This is a free-text field, and not a pointer field! This was done to ensure that monitors could be deleted without creating broken pointers. | |
2 | action | 0;2 | SET OF CODES | E:TOO EARLY I:INACTIVE Q:QD NEW JOB X:ERROR R:RUNNING M:M CHK FAIL | When a monitor is checked, the master job either starts a background job for the monitor, or it doesn't. If it does, record is made of the fact in this field. If a monitor job is not started, the reason is also recorded in this field. (The Results field (#5) often holds additional information about the action taken by the master job for a specific monitor.) | |
3 | check/queue time | 0;3 | DATE-TIME | This field holds the time the master job checked the monitor. | ||
4 | task number | 0;4 | NUMERIC | This field holds the task number of the queued monitor job created by the master job. | ||
5 | results | 0;5 | SET OF CODES | XE:ERROR-OTHER XM:ERROR-M CODE F:FINISHED XL:ERROR-LOCK | This field holds the additional information about the action taken by the master job for the specific monitor recorded in multiple entries. | |
6 | results time | 0;6 | DATE-TIME | This field holds the time the RESULTS field is populated. | ||
7 | error reason | 0;7 | FREE TEXT | This field holds optional free-text data that further illuminates the actions taken by the master job. | ||
8 | event job ien (free-text) | 0;8 | FREE TEXT | This field holds the task number of the background job created by the master job for a specific monitor. When monitor jobs complete, their record is deleted by Taskman. For this reason, this field is a free-text field, avoiding broken pointers. |
Error: Invalid Global File Type: 776.2051