VistA Analysis » VistA Reference » RPCs » MPIF CHANGE CMOR
MPIF CHANGE CMOR
This remote procedure call (RPC) allows the changing/updating of the COORDINATING MASTER OF RECORD (#991.03) field in the PATIENT (#2) file for a specific patient. An A08 Update message can also be triggered.
Properties
Property | Value |
---|---|
Label | RCCMOR |
MUMPS Implementation | MPIFRPC |
Return Type | SINGLE VALUE |
Input Parameters
Name | Type | Maximum Data Length | Required | Description |
---|---|---|---|---|
ICN | LITERAL | 10 | true | ICN - not including the checksum |
CMOR | LITERAL | 3 | true | The station number of the site that is to become the CMOR |
SSN | LITERAL | 9 | true | Social Security Number for the patient that is to be changed. SSN willonly be used if ICN is not found to check if the problem is with the AICNx-ref on the ICN field. |
A08 | LITERAL | 1 | true | This field will serve as a flag to note whether or not an A08 update message should be triggered. |
Document generated on August 31st 2022, 2:55:43 pm