This API allows saving of patient responses to a test or interview in the M database. The patient ien, the test code, and administration date is required along with the responses. All responses are checked for validity. No scoring is returned but successful addition to the M database is indicated. Input: DFN : patient internal identifier CODE: Test code from file 601 or “ASI” e.g. “CAGE”, “BDI”ADATE: inclusive administration date in %DT acceptable format (11/11/2011) Staff: DUZ of professional ordering the testR1: string of patient responses 1-200 R2: string of patient responses 201-400 [as needed] R3: string of patient responses 401-600 [as needed] Output:Array(1)=[DATA] indicates successful call