Files > COLLECTION SAMPLE

name
COLLECTION SAMPLE
number
62
location
^LAB(62,
description
Collection samples for laboratory specimens.
Fields
#NameLocationTypeDetailsIndexDescription
.01name(+)0;1FREE TEXTBThe name of the collection sample.
2default specimen0;2POINTER61This is the specimen that will appear as the default specimen for this collection sample. This does not preclude other specimens from being used but, rather, if it is the most frequently used one, it will save time and keystrokes for the user. collection sample. This does not preclude other specimens from being used but, rather, if it is the most frequently used one, it will save time and keystrokes for the user.
3tube top color0;3FREE TEXTCThe common color description of the tube used for this sample.
4volume large0;4NUMERICThe volume required for this sample.
5volume small0;5NUMERICThe volume required for this sample if an alternate small tube is used.
6lab section0;6POINTER62.2The functional section of the lab that this sample is associated with. Points to FILE #62.2.
7can lab collect0;7BOOLEAN0:NO
1:YES
If the Lab is allowed to collect this sample, this field must contain a YES entry.
8synonym1;0MULTIPLE62.01This is a multiple field. Enter synonyms, abbreviations, or common misspellings of this sample.
20snomed ct idSCT;1FREE TEXTFThis is the SNOMED CT concept identifier for this entry. If this entry is null then the entry is either unmapped or no valid SNOMED concept term exists to map this term. This field is only editable by the Lab software.
21sct code statusSCT;2SET OF CODESP:PREFERRED TERM
S:SYNONYM
L:LOCAL
R:REFERRED
X:NO APPLICABLE MAPPING
LN:NEW TERM PENDING LEXICON UPDATE
RN:STS REQUEST NEW CODE
E:ERROR
ACThis field indicate the status or disposition of this entry. P = SNOMED Preferred term S = SNOMED Synonym term L = Local spelling of a SNOMED term (miss-spelled) R = Referred to national coders to determine if acceptable X = No applicable mapping LN = New term pending LEXICON release/update. RN = STS Request New Code E = Error encountered when applying STS disposition to file entry.
22sct top conceptSCT;3POINTER64.061This field Identifies the SNOMED CT top level concept for this SNOMED code. This is useful to determine the proper code when the spelling of the terms are identical but have different concept (meaning).
23sct status dateSCT1;0MULTIPLE62.023This field track the status of terms referred to the STS team to determine if this code is a valid VHA SNOMED SCT term.
64.9101inactive date64.91;1DATE-TIMEThis is the date on or after which the entry will no longer be active. Inactive entries will not be available for selection in CPRS nor be able to be associated with a test in the LABORATORY TEST file (#60).
500collection wkld code9;0MULTIPLE62.02 This field is used for those unique situations when an accession WKLD code can not be used. For example Bacterial culture test. By using this field you don't have to enter collection samples in file 60 (LABORATORY TEST).

Referenced by 4 types

  1. LABORATORY TEST (60) -- lab collection sample
  2. TOPOGRAPHY FIELD (61) -- collection sample
  3. LAB PENDING ORDERS ENTRY (69.6) -- collection sample
  4. PROTOCOL (101) -- file link