# | Name | Location | Type | Details | Index | Description |
---|---|---|---|---|---|---|
.01 | date/time(+) | 0;1 | DATE-TIME | B | This field identifies the date and time the procedure was entered into the database. | |
.5 | ep record(+) | 0;2 | POINTER | 691.8 | C | This field identifies the EP record identifier. |
.9 | intervention | 0;3 | POINTER | 693.6 | This field documents intervention necessary for this procedure. | |
1 | premedication | 0;4 | FREE TEXT | This field documents the medication given before the procedure. | ||
2 | ekg | 6;0 | MULTIPLE | 692.02 | This field identifies the EKG which is associated with this procedure. | |
3 | entry site | 0;6 | POINTER | 697 | This field identifies the anatomical location of the catheter entry. | |
4 | recording site | 0;7 | POINTER | 693.5 | This field identifies the anatomical location of the recording site. | |
5 | pacing site | 0;8 | SET OF CODES | RVA:RT VENTRICULAR APEX RVOT:RT VENTRICULAR OUTFLOW TRACT LV:LEFT VENTRICLE | This field identifies the anatomical location of the pacing site. | |
6 | ventricular threshold (ma) | 0;9 | NUMERIC | This field identifies the ventricular threshold in milliamperes. | ||
7 | drive cycle length | 1;0 | MULTIPLE | 692.07 | This field identifies the drive cycle length. | |
8 | burst pacing (#rep. responses) | 2;1 | FREE TEXT | This field identifies the burst pacing (#rep. responses). | ||
9 | shortest burst cl | 2;2 | NUMERIC | This field identifies the shortest burst CL. | ||
10 | v.t.? | 2;3 | SET OF CODES | Y:SUS. V-T INDUCED N:NO V-T INDUCED N-S:NON-SUS. V.T. INDUCED | This documents the occurrance of ventricular tachycardia. | |
11 | initiation sequence of vt | 2;4 | FREE TEXT | This defines the initiation of VT. | ||
12 | duration of vt/vf | 2;5 | NUMERIC | This field identifies the duration of VT/VF. | ||
13 | v-t axis | 2;6 | FREE TEXT | This field identifies the V-T axis. | ||
14 | v-t cycle length | 2;7 | NUMERIC | This field identifies the V-T cycle length. | ||
15 | v-t morphology | 2;8 | SET OF CODES | R:RBBB L:LBBB N:NON DESC. V:VARIABLE | This field identifies the V-T morphology. | |
16 | term. v-t | 2;9 | SET OF CODES | C:EXTERNAL CARDIOVERSION P:PACED OUT S:SELF TERMINATION C+P:CARDIOVERSION+PACE OUT C+S:CARDIOVERSION+SELF TERM P+S:PACE OUT+SELF TERM IC:INTERNAL CARDIOVERSION | This field identifies the term V-T. | |
17 | pace out cycle length of v-t | 2;10 | NUMERIC | This field identifies the pace out cycle length of V-T. | ||
18 | cardioversion (j) | 2;11 | FREE TEXT | This documents whether cardioversion was necessary. | ||
19 | discharge date | 4;0 | MULTIPLE | 692.019 | This field identifies the discharge date. | |
20 | comment | 3;0 | WORD-PROCESSING | This field identifies the comment field. | ||
21 | cardiology staff | 5;1 | POINTER | 200 | This field identifies the cardiology staff assigned to this case. | |
700 | icd diagnosis | ICD;0 | MULTIPLE | 692.03 | This field contains the ICD Diagnosis(es) for the procedure. | |
701 | primary provider | PROV;1 | POINTER | 200 | This contains the primary provider. It is triggered by another field in the file and is located here to provider a standard provider location for use in transferring data to the PCC. |
Not Referenced