Files > BPS SETUP

name
BPS SETUP
number
9002313.99
location
^BPS(9002313.99,
description
Parameters that apply to all of ECME. There should only be one record with IEN=1 and name MAIN SETUP ENTRY. Per VHA Directive 2004-038, this file definition should not be modified.
Fields
#NameLocationTypeDetailsIndexDescription
.01name(+)0;1FREE TEXTB
.04date site last registered0;4DATE-TIMEThis is automatically populated every time the site is registered. The date/time in this field is the last time a registration message was transmitted to Austin for this site.
.05insurer asleep interval(+)0;5NUMERICThis is the number of minutes to retry claims for a payer sheet while the payer is identified as being unavailable to process claims. 0 = do not implement asleep processes.
.06insurer asleep retries(+)0;6NUMERICThis is the number of times an asleep probe should be done on a payer before the claims are marked as Rejected. 0 = Asleep process turned off
.07date site last confirmed0;7DATE-TIMEThis field is populated every time the site is confirmed registered by Austin. This is automatically populated when the application ACK message is returned from Austin.
.08default eligibility pharmacy0;8POINTER9002313.56This is the default BPS PHARMACY that will be used for eligibility verification submissions when the submission is not associated with an RX/Fill.
3.01ecme timeout(+)0;2NUMERICThis is the maximum number of seconds used for the display of the claims processing status. After this time, claims processing will continue but the user will not see messages indicating the progress of the claim.
3.02payer response test mode0;3SET OF CODES1:ON
0:OFF
This field enables the testing of Payer Response Overrides - 1 for On, 0 (or "") for Off. This should never be ON at a production site.
2341.01winnow testing flagWINNOW;1BOOLEAN0:NO
1:YES
This flag controls whether purging is really done or just in test mode. YES sets test mode on and NO enables purging.
2341.03winnow bps logWINNOW;3NUMERICNumber of days of the BPS LOG to keep on the system.
2500certifierCERTIFIER;1POINTER200Contains the name of the person performing certification.
6000site contactVITRIA;1POINTER200This is the Site Contact for Vitria. Usually an IT staff person.
6001alternate site contactVITRIA;2POINTER200This is the name of the Alternate Contact person for the site in relation to Vitria.
6003vitria interface versionVITRIA;3FREE TEXTEnter the Vitria supplied interface version number.
9999site type(+)SITE TYPE;1SET OF CODES0:VA
1:IHS
This field is used to determine whether the site is a Veterans Administration site or and Indian Health Services Site. Based on this answer, the ECME system will process in two different manners with respect to claims generation and data collection methods.
10000last sequence3;1NUMERICUsed to sequence the transmission ID's to ensure they are unique for the site.

Not Referenced